ANENG Smart Clamp Meter Multimeter PN135 Car AC/DC Voltage Current 4000 Counts Ammeter voltmeter NCV Ohm Capacitance Test Tools
Description:
This digital clamp meter is a 4000 bit true effective value, automatic intelligent digital clamp meter that does not require rotating the dial selection function. According to the different input voltage/current/resistance, the instrument automatically recognizes and measures. The machine has stable performance, high precision, high reliability, clear readings, and overload protection function. Powered by 2 AAA 1.5V batteries, this instrument adopts a large screen LCD display. This meter is compact and easy to carry. It can automatically recognize DC voltage and AC voltage, AC current, resistance, on-off, and does not require any switching. It can also be manually switched to measure DC voltage, AC voltage, AC current, capacitance, diode, on-off, electric field induction (NCV), live wire discrimination (LIVE) and other functions. It is a high-performance tool and an ideal tool for laboratories, factories, radio enthusiasts, and households.
AC current measurement:
1. Press the "SEL" button for more than 2 seconds to turn on the device, and the instrument will display "Auto". Press the trigger, open the clamp head, place the wire in the clamp, close the clamp head, and the current value of the wire can be measured. Simultaneously clamping two or three wires cannot be measured.
2. To ensure measurement accuracy, please place the measured conductor at the center position inside the clamp.
3. The main display of the LCD screen shows current measurement data.
4. Automatic recognition of measured current 0.3A: If a lower current needs to be measured, it can be measured by short pressing
The "SEL" button switches to AC current mode for measurement.
Attention:
2.5A
2. Under current measurement, the test probe between "INPUT" and "COM" should be unplugged.
DC voltage measurement:
1. Press and hold the "SEL" button for more than 2 seconds to turn on the device, and the instrument panel will display "Auto"
2. Insert the red probe into the "INPUT" socket and the black probe into the "COM" socket.
3. Connect the probe to the power supply or load to be tested, and the polarity of the red probe terminal will be displayed simultaneously
Displayed on the monitor.
4. The main display of the LCD screen shows the measured DC voltage data.
5. The automatic recognition of the measured voltage should be ≥ 0.8V: if a lower voltage needs to be measured, a short technique can be used
When measuring high voltage, hands should not touch the metal parts of the probe to avoid the risk of electric shock.
Attention:
Do not input voltage higher than 600V, as it may display higher voltage but there is a risk of damaging the internal wiring of the instrument.
When measuring high voltage, hands should not touch the metal parts of the probe to avoid the risk of electric shock.
Resistance measurement:
1. Press and hold the "Heart/SEL" button for more than 2 seconds to turn on the device, and the instrument panel will display "Auto".
2. Insert the red probe into the "INPUT" socket and the black probe into the "COM" socket.
3. Connect the probe to the measured resistor.
4. The main display of the LCD screen shows the measured resistance value.
Attention:
If the measured resistance value exceeds the maximum value of the measuring range, the display will show "0L".
When checking the online resistance, all power sources in the measured circuit must be turned off first and all capacitors must be fully discharged.
Specification:
Function
Range
Resolution
Precision
AC voltage
0.01V-600V
0.01V
土(1.0%+5)
DC voltage
0.1V-600V
0.01mV
±(0.8%+5)
AC current
0.01A-600A
0.01A
±(2.5%+10)
Resistance
0.1Ω-40MΩ
0.1Ω
+(0.8%+5)
Capacitance
10nF-40mF
40pF
土(4.0%+5)
NCV voltage induction
√
Battery
1.5V AAA Battery*2
Data hold
√
LIVE Naught Line
√
On/off buzzing
√
Backlight bright screen
√
Diode tube
√
Low power waming
√
Max Count
4000 Counts
Flashlight illumination
√
Material
ABS
Low batfery indication
√
Automatic shutdown
If there is no operation within 15 minutes after starting upthe instrument will automatically shut down
Package Include(without Battery)
1 * Test pen line
1 * Instructions
16 in 1 Combination Line